System Overview
3.1 Electrical Ratings and Specifications
Manufactured By
AlarmSaf
65A Industrial Way
Wilmington, MA 01887
Tel: 800 987 1050
978 658 6717
Fax: 978 658 8638
www.alarmsaf.com
Model Numbers
RMMV Series
Electrical Ratings and Specifications
1.6 Amp
4A @ 24V
4A @ 12V
12.5/10 Amp
AC
8 x 12/24
VDC
16 x 24/28
VAC
4.2
Amp
120
VAC
RMMV-122428-24
PTC Protected Outputs
3 Amp
4A @ 24V
4A @ 12V
12.5/10 Amp
AC
8 x 12/24
VDC
16 x 24/28
VAC
4.2
Amp
120
VAC
RMMV-122428-24F
Maximum
Current
per Zone
Max Total DC
Output
Current *
Max Total AC
Output
Current
DC ZonesAC Zones
Max
Input
Current
Nominal
Input
Voltage
Model #
Fuse Protected Products
* - Note: Maximum total DC load of 12V and 24V supplies must not exceed 4A maximum.
Current drawn from the 12V supply must be subtracted from the 24V supply’s available
current.
Product Use
When installed in accordance with all standards listed in Section 2 of this document, the AlarmSaf
RMMV Power Supply line provides AC power for cameras and related accessories or other AC
powered devices and DC power for DC CCTV cameras, access control equipment, IT equipment and
related accessories, or other DC powered devices.